TL045 Temperature sensor
This small sensor consists of a Pt100 / Pt500 resistor, capsuled in a metal shield. The TL045 can be used both for direct mounting together with a mounting kit and also (without this kit) for mounting in pockets. The sensors are delivered, as standard, with a 2 metres cable. They can be mounted in a flow sensor or in ball valves or T-tubes.
The sensors can be delivered for 2-or 4-wire measurment.
| Technical data | Download | ||||
- The sensors have an extreme short response time due to the small thermal mass.
- The sensors are delivered in pairs with permitted difference of max. 0,05 K and providing a median of 0,02 K in production and by final inspection.
- It is strongly recommended that the pair of sensors are mounted in identical way using T-pieces or ball-valves alternatively.
- The equality in mounting and performance will support the accuracy in measurement of temperature difference.
- The ball valves offer the possibility to exchange the sensors without big loss of water. The installation must be properly sealed.
- Data sheet Download (pdf) 117 KB